Gas Turbine Engines
Baker Hughes – Brush Power Generation
The integration of Brush Power Generation enhances Baker Hughes’ electrification offering and supports strategic commitment to provide cleaner energy solutions.
Model | Output Range (kW) min | max | # Poles | Voltage Range (kV) min | max | Motor Type | Freq. Hz | VFD Operation | Speed Range For VFD Operation min | max | Motor Efficiency (%) At Rated Operating Point | Normal Power Factor (cos Phi) At Rated Operating Point | Explosion Point Avail. | Cooling Air/Air, Air/Water |
30,000 | 40,000 | 2 | 6 | 16 | SM | 50 /60 Hz | Y | 2400 | 3780 | 98.15% | 0.95 | Y | A/A, A/W |
40,000 | 63,000 | 2 | 6 | 16 | SM | 50 /60 Hz | Y | 2400 | 3780 | 98.40% | 0.95 | Y | A/A, A/W |
63,000 | 75,000 | 2 | 6 | 16 | SM | 50 /60 Hz | Y | 2400 | 3780 | 98.40% | 0.95 | Y | A/A, A/W |
75,000 | 100,000 | 2 | 6 | 16 | SM | 60Hz | Y | 2520 | 3780 | 98.40% | 0.95 | Y | A/A, A/W |
75,000 | 100,000 | 2 | 6 | 16 | SM | 50Hz | Y | 2400 | 3150 | 98.25% | 0.95 | Y | A/A, A/W |
Baker Hughes Steam Turbines
Proven modular designs with the flexibility to meet operating challenges across the oil and gas, and power generation industries
Model | Output Range kW min | Output Range kW max | Cycle Type | Frame Configuration (E)xtraction or (I)njections | Frame Configuration Single Flow or Double Flow | Maximum Inlet Steam Pressure bar | Maximum Inlet Temperature °C | Maximum Steam Flow kg/s | Speed Range RPM max |
2000 | 100,000 | Back Pressure | I | SF | 140 | 565 | 180 | 16,000 |
2000 | 100,000 | Back Pressure | E/I | SF | 140 | 565 | 180 | 16,000 |
2000 | 150,000 | Condensing | I | SF | 140 | 565 | 220 | 16,000 |
2000 | 150,000 | Condensing | E/I | SF | 140 | 565 | 220 | 16,000 |
5000 | 80,000 | Condensing | I | DF | 30 | 300 | 100 | 16,000 |
2000 | 35,000 | Back Pressure | I | SF | 30 | 300 | 180 | 16,000 |
2000 | 60,000 | Condensing | I | SF | 30 | 300 | 180 | 16000 |
5000 | 60,000 | Condensing | I | DF | 30 | 300 | 100 | 16,000 |
500 | 6000 | Condensing | E/I | SF | 90 | 500 | | 15,000 |
500 | 6000 | Back Pressure | E/I | SF | 90 | 500 | | 15,000 |
5000 | 30,000 | Condensing | | SF | 280 | 575 | | 6,000 |
2000 | 45,000 | Condensing | E/I | SF | 140 | 540 | | 15,000 |
2000 | 40,000 | Back Pressure | E/I | SF | 140 | 540 | | 15,000 |