Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3016 |
8 V |
50 |
1,500 |
18.9 |
400 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3016 |
12 V |
50 |
1,500 |
18.9 |
600 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3016 |
16 V |
50 |
1,500 |
18.8 |
800 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3016 S |
16 V |
62.5 |
1,500 |
23.5 |
1,000 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 2020 |
12 V |
83 |
1,500 |
15.5 |
1,000 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 2020 K1 |
12 V |
83 |
1,500 |
15.5 |
1,000 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 2020 K |
12 V |
93.75 |
1,500 |
17.4 |
1,125 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 2020 |
12 V |
100 |
1,500 |
18.6 |
1,200 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 2020 K |
16 V |
93.75 |
1,500 |
17.5 |
1,500 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 2020 |
16 V |
97.5 |
1,500 |
18.1 |
1,560 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 2020 |
20 V |
100 |
1,500 |
18.6 |
2,000 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3020 |
12 V |
115 |
1,500 |
21.5 |
1,380 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3020 R |
12 V |
115 |
1,500 |
21.5 |
1,380 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3020 |
16 V |
115 |
1,500 |
21.5 |
1,840 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3020 R |
16 V |
115 |
1,500 |
21.5 |
1,840 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3020 |
20 V |
115 |
1,500 |
21.5 |
2,300 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3020 R |
20 V |
115 |
1,500 |
21.5 |
2,300 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3020 PV |
20 V |
100 |
1,500 |
18.6 |
2,000 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 3020 RV |
20 V |
100 |
1,500 |
18.6 |
2,000 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 2032 |
12 V |
278 |
1,000 |
20 |
3,333 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 2032 |
16 V |
269 |
1,000 |
19.4 |
4,300 |
PG |
|
Caterpillar Energy Solutions GmbH / MWM |
SI FF (admixing) |
TCG 2032B |
16 V |
281 |
1,000 |
20.3 |
4,500 |
PG |
|
INNIO’s Jenbacher engines |
SI - H2 (100%) |
J412 |
12V |
50 |
1800 |
13.5 |
600 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (100%) |
J416 |
16V |
50 |
1800 |
13.5 |
800 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (100%) |
J420 |
20V |
50 |
1800 |
13.5 |
1000 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J208 GS |
8L |
43.6 |
1800 |
16.5 |
335 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J312 GS |
12V |
54.8 |
1800 |
18 |
635 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J316 GS |
16V |
54.8 |
1800 |
18 |
851 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J320 GS |
20V |
54.8 |
1800 |
18 |
1067 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J412 GS |
12V |
80 |
1800 |
21 |
935 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J416 GS |
16V |
80 |
1800 |
21 |
1245 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J420 GS |
20V |
80 |
1800 |
21 |
1560 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J612 GS |
12V |
171.5 |
1500 |
22 |
2007 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J616 GS |
16V |
171.6 |
1500 |
22 |
2679 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J620 GS |
20V |
171.6 |
1500 |
22 |
3360 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J624 GS |
24V |
191.4 |
1500 |
24.6 |
4507 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
SI - H2 (admixing) up to 25 (vol)% Hydrogen |
J920 GS |
20V |
528.4 |
1000 |
24 |
10600 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J208 GS |
8L |
43.6 |
1800 |
16.5 |
335 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J312 GS |
12V |
54.8 |
1800 |
18 |
635 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J316 GS |
16V |
54.75 |
1800 |
18 |
851 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J320 GS |
20V |
54.8 |
1800 |
18 |
1067 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J412 GS |
12V |
80 |
1800 |
21 |
935 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J416 GS |
16V |
80 |
1800 |
21 |
1245 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J420 GS |
20V |
80 |
1800 |
21 |
1560 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J612 GS |
12V |
171.5 |
1500 |
22 |
2007 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J616 GS |
16V |
171.6 |
1500 |
22 |
2679 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J620 GS |
20V |
171.6 |
1500 |
22 |
3360 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J624 GS |
24V |
191.4 |
1500 |
24.6 |
4507 |
PG |
MCP-D |
INNIO’s Jenbacher engines |
biomethane |
J920 GS |
20V |
528.4 |
1000 |
24 |
10600 |
PG |
MCP-D |
MAN Energy Solutions |
FF (up to 25% H2) |
35/44GTS |
12V |
640 |
750 |
|
7680 |
PG |
WB2007/2008; 13. BImschV / 44. BImschV & IED (LCP, 2017) w. exhaust gas treatment |
MAN Energy Solutions |
FF (up to 25% H2) |
35/44GTS |
20V |
640 |
750 |
|
12800 |
PG |
WB2007/2008; 13. BImschV / 44. BImschV & IED (LCP, 2017) w. exhaust gas treatment |
MAN Energy Solutions |
FF (up to 25% H2) |
51/60G |
18V |
1150 |
514 |
|
20700 |
PG |
WB2007/2008 / 13. BImschV / 44. BImschV & IED (LCP, 2017) w. exhaust gas treatment |
MAN Energy Solutions |
FF (up to 25% H2) |
51/60GTS |
18V |
1150 |
514 |
|
20700 |
PG |
WB2007/2008 / 13. BImschV / 44. BImschV & IED (LCP, 2017) w. exhaust gas treatment |
MAN Energy Solutions |
DF (25%H2) |
49/60DF |
9L |
|
|
|
|
PG |
WB2007/2008; 13. BImschV / 44. BimschV & IED (LCP, 2017) w. exhaust gas treatment |
MAN Energy Solutions |
DF (25%H2) |
49/60DF |
14V |
|
|
|
|
PG |
WB2007/2008; 13. BImschV / 44. BimschV & IED (LCP, 2017) w. exhaust gas treatment |
MAN Energy Solutions |
DF (25%H2) |
49/60DF |
20V |
|
|
|
|
PG |
WB2007/2008; 13. BImschV & IED (LCP, 2017) w. exhaust gas treatment |
MAN Energy Solutions |
SI (25%H2) |
49/60G |
14V |
|
|
|
|
PG |
WB2007/2008; 13. BImschV / 44. BImschV & IED (LCP, 2017) w. exhaust gas treatment |
MAN Energy Solutions |
SI (25%H2) |
49/60G |
20V |
|
|
|
|
PG |
WB2007/2008; 13. BImschV & IED (LCP, 2017) w. exhaust gas treatment |
TEDOM a.s. |
SI - Natural Gas |
KG 35 G5V NX 88 |
4V |
8.75 |
1500 |
7.43 |
35 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
KB 30 G5V NX 88 |
4V |
8 |
1500 |
6.79 |
32 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Propane |
KP 30 G5V NX 88 |
4V |
8 |
1500 |
6.79 |
32 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
MB 50 G5V NX 88 |
4V |
12 |
1500 |
8.38 |
48 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Propane |
MP 50 G5V NX 88 |
4V |
13 |
1500 |
9.08 |
52 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 85 G5V NX 86 |
6V |
14.33 |
1500 |
5.76 |
86 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
TB 90 G5V NX 86 |
6V |
14.67 |
1500 |
5.89 |
88 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Propane |
TP 90 G5V NX 86 |
6V |
14.83 |
1500 |
5.96 |
89 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Syngas |
TW 80 G5V NX 86 |
6V |
13.33 |
1500 |
5.36 |
80 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 110 G5V TX 86 |
6V |
18.33 |
1500 |
7.37 |
110 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
TB 110 G5V TX 86 |
6V |
18.67 |
1500 |
7.5 |
112 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Syngas |
TW 110 G5V TX 86 |
6V |
18.5 |
1500 |
7.43 |
111 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 130 G5V TX 86 |
6V |
22 |
1500 |
8.84 |
132 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
TB 130 G5V TX 86 |
6V |
21.67 |
1500 |
8.71 |
130 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Propane |
TP 120 G5V TX 86 |
6V |
24 |
1500 |
9.64 |
144 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Syngas |
TW 150 G5V TW 86 |
6V |
25 |
1500 |
10.05 |
150 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Propane |
TP 160 G5V TW 86 |
6V |
26.5 |
1500 |
10.65 |
159 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 170 G5V TW 86 |
6V |
28.83 |
1500 |
11.59 |
173 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
TB 170 G5V TW 86 |
6V |
29.33 |
1500 |
11.79 |
176 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 190 G5V TW 86 |
6V |
32.17 |
1500 |
12.92 |
193 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
TB 190 G5V TW 86 |
6V |
31.83 |
1500 |
12.79 |
191 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 210 G5V TW 86 |
6V |
35.5 |
1500 |
14.26 |
213 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
TB 210 G5V TW 86 |
6V |
35.5 |
1500 |
14.26 |
213 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
SG 160 G5V TW 86/87 |
5V |
31.4 |
1500 |
13.51 |
157 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
SB 160 G5V TW 86 |
5V |
31.4 |
1500 |
13.51 |
157 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
SG 230 G5V TW 86/87 |
6V |
38.33 |
1500 |
14.44 |
230 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
SB 265 G5V TW 86 |
6V |
44.17 |
1500 |
16.64 |
265 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
SB 275 G5V TW 86 |
6V |
45.83 |
1500 |
17.27 |
275 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
SB 320 G5V TW 86 |
8V |
40 |
1500 |
15.61 |
320 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
SB 365 G5V TW 86 |
8V |
45.63 |
1500 |
17.8 |
365 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 80 G5V NX 88 |
6V |
13.33 |
1500 |
5.36 |
80 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 100 G5V NX 88 |
6V |
16.67 |
1500 |
6.7 |
100 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 110 G5V NX 88 |
6V |
18.33 |
1500 |
7.37 |
110 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 120 G5V NX 88 |
6V |
20 |
1500 |
8.04 |
120 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 130 G5V NX 88 |
6V |
21.67 |
1500 |
8.71 |
130 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
MG 185 G5V NX 88 |
8V |
22.88 |
1500 |
8.52 |
183 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
MG 320 G5V TW 88 |
12V |
26.67 |
1500 |
9.93 |
320 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 100 G8V NX 86 |
6V |
16.33 |
1800 |
5.47 |
98 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
TB 100 G8V NX 86 |
6V |
16.5 |
1800 |
5.52 |
99 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 150 G8V TX 86 |
6V |
25.5 |
1800 |
8.54 |
153 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
TB 150 G8V TX 86 |
6V |
24.67 |
1800 |
8.26 |
148 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 200 G8V TW 86 |
6V |
33.67 |
1800 |
11.27 |
202 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Biogas |
TB 200 G8V TW 86 |
6V |
33.33 |
1800 |
11.16 |
200 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |
TEDOM a.s. |
SI - Natural Gas |
TG 150 G8V NX 88 |
6V |
26 |
1800 |
8.71 |
156 |
ST-IND (CHP/genset) |
TA-Luft, 44. BImSchV |